I'd think the problem with the PSUs is not the temp sensor, but one of the capacitors or perhaps the dual diode. Those parts seem to fail with age more often.
Hello Lisa fellowers,
I have some repair questions I nowhere found in the well known Lisa documentation... it may be also helpful for others.
1.) I have 2 1.8AMP power supplies that shut down after 5-10 minutes when they are warmed up. When they are warm the Lisa shuts down immediately; if you wait 1h or so it runs again for some minutes.
I read in the owners guide that the PS has a temperature sensor that shuts down the PS if the temperature is over 90°centigrade. My question: where the hell can I find that sensor on the PS? Can you tell me the location? Any experiences with that part?
2.) One Lisa always shows error #52 when starting. The problem is that the COPS chip is not the problem (changed i/o, MB, CPU boards.. and everything with another working Lisa where this problem does not exist). I can only imagine that the cabels inside or the power on/off switch causes this problem. Any experiences with that sympthom?
many thanks for any answers
Rudi
--
-----
You received this message because you are a member of the LisaList group.
The group FAQ is at http://lowendmac.com/lists/lisa.html
To post to this group, send email to lisalist@googlegroups.com
To leave this group, send email to lisalist+unsubscribe@googlegroups.com
For more options, visit this group at http://groups.google.com/group/lisalist